Thin wall blind hole architecture, high precision, strong anti-deflective loading, good shock resistance, simple to install, moistureproof sealed, ideal for hostile environment.
| Technical Parameter | |
| Rated Load | 10-50t | 
| Sensitivity | 2.0000±0.002mV/V | 
| Total Error | ±0.02%F.S | 
| Creep(30minutes) | ±0.02%F.S | 
| Recommended Excitation Voltage | 5V~12V(AC or DC) | 
| Maximum Excitation Voltage | 15V(AC or DC) | 
| Zero Balance | ±1%F.S | 
| Input Impedance | 380±10Ω | 
| Output Impedance | 350±5Ω | 
| Insulation Impedance | ≥5000MΩ | 
| Safe Overload | 150%F.S | 
| Ultimate Overload | 200%F.S | 
| Operating Temperature Range | (-30~+70)℃ | 
| Compensated Temperature Range | (-20~+60)℃ | 
| Temperature Effect On Load | ±0.02%F.S/10℃ | 
| Temperature Effect On Zero | ±0.02%F.S/10℃ | 
| Construction | Alloy Steel | 
| Protection Class | IP67&IP68 | 
| Citation | GB/T7551-2008/OIML R60 | 
| Mode of Connection | input+: Input+:Red input-: Input-:Black output+: Output+:Green output-: Output-:White |